factory low price Irregular Silica Flash Column - SepaFlash™ HP Series – Santai

factory low price Irregular Silica Flash Column - SepaFlash™ HP Series – Santai

Short Description:


Product Detail

Application

Video

catalogue

Related Video

Feedback (2)

Fast and fantastic quotations, informed advisers to help you choose the correct products that suits all your needs, a short manufacturing time, responsible good quality control and distinct companies for paying and shipping affairs for Related Brand Biotage, Flash Chromatography Separation, Related Brand Buchi, Your inquiry will be highly welcomed and a win-win prosperous development are what we are expecting.
factory low price Irregular Silica Flash Column - SepaFlash™ HP Series – Santai Detail:

HP series flash columns are spin-welded and allow for higher pressure of up to 400 psi. Available adapter facilitates compatibility with any flash system on the market. This series provides Luer-Lok in and Luer-Lok out flexibility for convenient column stacking. When pre-packed with high-efficiency silica gel (irregular, 25-40 μm, 60 Å; spherical, 20-45 μm, 70 Å), this series presents an outstanding resolution over conventional flash cartridges.

※ Solid, one-piece polypropylene body with thick walls for safety
※ Freely choose irregular silica or spherical silica according to your personal preference
※ Markedly improved resolution and higher sample loading capability
※ Spherical silica provides improved performance without increasing the system backpressure

For spherical silica gel, strict quality controls from raw material to finished product ensures high lot-to-lot reproducibility and tightly controlled specifications.

※Consistency, reliability, reproducibility
※No contamination, lower backpressure 
※Superior resolution
※Symmetrical peaks with no tailing
※Higher sample loading capacity

spherical

UltraPure irregular silica, 40−63 µm, 60 Å (surface area 500 m2 /g, pH 6.5–7.5, loading capacity 0.1–10%)

Item Number Column Size Sample Size(g) Flow Rate(mL/min) Cartridge Length (cm) Cartridge ID (mm) Max. Pressure(psi/bar) Quantity per Box
Small Big
SW-5101-004 4 g 4 mg–0.4 g 15–40 113.8 12.4 400/27.5 24 120
SW-5101-012 12 g 12 mg–1.2 g 30–60 134.8 21.4 400/27.5 24 108
SW-5101-025 25 g 25 mg–2.5 g 30–60 184 21.4 400/27.5 18 72
SW-5101-040 40 g 40 mg–4.0 g 40–70 184.4 26.7 400/27.5 12 48
SW-5101-080 80 g 80 mg–8.0 g 50–100 257.4 31.2 350/24.0 10 20
SW-5101-120 120 g 120 mg–12 g 60–150 261.5 38.6 300/20.7 8 16
SW-5101-220 220 g 220 mg–22 g 80–220 223.5 61.4 300/20.7 4 8
SW-5101-330 330 g 330 mg–33 g 80–220 280.2 61.4 250/17.2 3 6

※ Compatible with all flash chromatography systems on the market.

High-efficiency irregular silica, 25−40 µm, 60 Å (surface area 500 m2 /g, pH 6.5–7.5, loading capacity 0.1–15%)

Item Number Column Size Sample Size(g) Flow Rate(mL/min) Cartridge Length (cm) Cartridge ID (mm) Max. Pressure(psi/bar) Quantity per Box
Small Big
SW-5102-004 4 g 4 mg–0.6 g 15–30 113.8 12.4 400/27.5 24 120
SW-5102-012 12 g 12 mg–1.8 g 25–50 134.8 21.4 400/27.5 24 108
SW-5102-025 25 g 25 mg–3.8 g 25–50 184 21.4 400/27.5 18 72
SW-5102-040 40 g 40 mg–6.0 g 30–60 184.4 26.7 400/27.5 12 48
SW-5102-080 80 g 80 mg–12 g 40–80 257.4 31.2 350/24.0 10 20
SW-5102-120 120 g 120 mg–18 g 45–90 261.5 38.6 300/20.7 8 16
SW-5102-220 220 g 220 mg–33 g 60–120 223.5 61.4 300/20.7 4 8
SW-5102-330 330 g 330 mg–50 g 60–120 280.2 61.4 250/17.2 3 6

※ Compatible with all flash chromatography systems on the market.

UltraPure spherical silica, 40−75 µm, 70 Å (surface area 500 m2 /g, pH 6.0–8.0, loading capacity 0.1–10%)

Item Number Column Size Sample Size(g) Flow Rate(mL/min) Cartridge Length (cm) Cartridge ID (mm) Max. Pressure(psi/bar) Quantity per Box
Small Big
SW-2101-004-SP 4 g 4 mg–0.4 g 15–40 113.8 12.4 400/27.5 24 120
SW-2101-012-SP 12 g 12 mg–1.2 g 30–60 134.8 21.4 400/27.5 24 108
SW-2101-025-SP 25 g 25 mg–2.5 g 30–60 184 21.4 400/27.5 18 72
SW-2101-040-SP 40 g 40 mg–4.0 g 40–70 184.4 26.7 400/27.5 12 48
SW-2101-080-SP 80 g 80 mg–8.0 g 50–100 257.4 31.2 350/24.0 10 20
SW-2101-120-SP 120 g 120 mg–12 g 60–150 261.5 38.6 300/20.7 8 16
SW-2101-220-SP 220 g 220 mg–22 g 80–220 223.5 61.4 300/20.7 4 8
SW-2101-330-SP 330 g 330 mg–33 g 80–220 280.2 61.4 250/17.2 3 6

※Compatible with all flash chromatography systems on the market.

High-efficiency spherical silica, 20−45 µm, 70 Å (surface area 500 m2 /g, pH 6.0–8.0, loading capacity 0.1–15%)

Item Number Column Size Sample Size(g) Flow Rate(mL/min) Cartridge Length (cm) Cartridge ID (mm) Max. Pressure(psi/bar) Quantity per Box
SW-2102-004-SP 4 g 4 mg–0.6 g 15–30 113.8 12.4 400/27.5 24
SW-2102-012-SP 12 g 12 mg–1.8 g 25–50 134.8 21.4 400/27.5 24
SW-2102-025-SP 25 g 25 mg–3.8 g 25–50 184 21.4 400/27.5 18
SW-2102-040-SP 40 g 40 mg–6.0 g 30–60 184.4 26.7 400/27.5 12
SW-2102-080-SP 80 g 80 mg–12 g 40–80 257.4 31.2 350/24.0 10
SW-2102-120-SP 120 g 120 mg–18 g 45–90 261.5 38.6 300/20.7 8
SW-2102-220-SP 220 g 220 mg–33 g 60–120 223.5 61.4 300/20.7 4
SW-2102-330-SP 330 g 330 mg–50 g 60–120 280.2 61.4 250/17.2 3

※Compatible with all flash chromatography systems on the market.

Purification of compounds that are difficult to separate by flash chromatography (ΔRf ≤ 0.2 between spots on TLC) often results in additional steps such as subsequent purification by preparative scale HPLC. It is possible to reduce the amount of additional work required for purification by simply stacking several prepacked SepaFlash™ columns end to end on a flash chromatography system.

In liquid chromatography, chemical species are separated on the basis of their differences in velocity as they move through the column. Increasing column length can significantly increase resolution. By stacking columns end to end the length to diameter (L to D) ratio is increased so that no major changes to the media and solvent system are necessary. Often this increased L to D is sufficient to provide successful separation of difficult mixtures due to close compounds retention time that is not obtained on a single column. The data illustrates the linear relationship between the resolution and overall column length.

HP1
HP

The Highest Purification Performance Available
HP series flash columns are precisely manufactured with high-capacity silica gel, and deliver the highest purification performance. The high-capacity spherical silica has 40% higher surface area, doubling the loading capacity of lower surface area silica.
※ High-capacity silica with 40% more surface area.
※ Higher loading means smaller, faster and cheaper cartridges can be used for any separation.
※ Less solvent required.
※ The highest peak resolution.

High-capacity spherical silica, 25 µm, 50 Å (surface area 700 m2 /g, pH 5.0–8.0, loading capacity 0.1–30%)

Item Number Column Size Sample Size(g) Flow Rate(mL/min) Cartridge Length (cm) Cartridge ID (mm) Max. Pressure(psi/bar) Quantity per Box
Small Big
SW-2102-004-SP(H) 4 g 4 mg–1.2 g 15–30 113.8 12.4 400/27.5 24 120
SW-2102-012-SP(H) 12 g 12 mg–3.6 g 25–50 134.8 21.4 400/27.5 24 108
SW-2102-025-SP(H) 25 g 25 mg–7.5 g 25–50 184 21.4 400/27.5 18 72
SW-2102-040-SP(H) 40 g 40 mg–12 g 30–60 184.4 26.7 400/27.5 12 48
SW-2102-080-SP(H) 80 g 80 mg–24 g 40–80 257.4 31.2 350/24.0 10 20
SW-2102-120-SP(H) 120 g 120 mg–36 g 45–90 261.5 38.6 300/20.7 8 16
SW-2102-220-SP(H) 220 g 220 mg–66 g 60–120 223.5 61.4 300/20.7 4 8
SW-2102-330-SP(H) 330 g 330 mg–99 g 60–120 280.2 61.4 250/17.2 3 6

※ Compatible with all flash chromatography systems on the market.

High-capacity spherical silica, 15 µm, 50 Å (NEW Product) (surface area 700 m2 /g, pH 5.0–8.0, loading capacity 0.1–30%)

Item Number Column Size Sample Size(g) Flow Rate(mL/min) Cartridge Length (cm) Cartridge ID (mm) Max. Pressure(psi/bar) Quantity per Box
Small Big
SW-2103-004-SP(H) 4 g 4 mg–1.2 g 10–15 113.8 12.4 400/27.5 24 120
SW-2103-012-SP(H) 12 g 12 mg–3.6 g 15–20 134.8 21.4 400/27.5 24 108
SW-2103-025-SP(H) 25 g 25 mg–7.5 g 15–20 184 21.4 400/27.5 18 72
SW-2103-040-SP(H) 40 g 40 mg–12 g 20–30 184.4 26.7 400/27.5 12 48
SW-2103-080-SP(H) 80 g 80 mg–24 g 30–40 257.4 31.2 350/24.0 10 20
SW-2103-120-SP(H) 120 g 120 mg–36 g 35–45 261.5 38.6 300/20.7 8 16
SW-2103-220-SP(H) 220 g 220 mg–66 g 50–65 223.5 61.4 300/20.7 4 8
SW-2103-330-SP(H) 330 g 330 mg–99 g 50–65 280.2 61.4 250/17.2 3 6

※ Compatible with all flash chromatography systems on the market.

Double Loading Capacity of SepaFlash™ Cartridges pre-packed with high-capacity silica gel (700 m2 /g for 50 Å pore size) delivers the highest purification performance. The high-capacity 25 µm or 15 µm spherical silica has 40% higher surface area, doubling the loading capacity of lower surface area silica. Santai evaluated the performance of the SepaFlash™ columns compared to two well-known brands. Results show SepaFlash™ outperforms the competitors.

HP3
HP4


Product detail pictures:

factory low price Irregular Silica Flash Column - SepaFlash™ HP Series – Santai detail pictures


Related Product Guide:

Our rewards are lower costs,dynamic profits team,specialised QC,potent factories,high-quality services for factory low price Irregular Silica Flash Column - SepaFlash™ HP Series – Santai , The product will supply to all over the world, such as: Mumbai, Qatar, Ecuador, Good quality and reasonable price have brought us stable customers and high reputation. Providing 'Quality Products, Excellent Service, Competitive Prices and Prompt Delivery', we are now looking forward to even greater cooperation with overseas customers based on mutual benefits. We'll work whole-heartedly to improve our solutions and services. We also promise to work jointly with business partners to elevate our cooperation to a higher level and share success together. Warmly welcome you to visit our factory sincerely.
  • As a veteran of this industry, we can say that the company can be a leader in the industry, select them is right.
    5 Stars By trameka milhouse from Niger - 2017.10.13 10:47
    We are old friends, the company's product quality has been always very good and this time the price is also very cheap.
    5 Stars By Michelle from New Orleans - 2017.08.18 18:38
    Write your message here and send it to us