Wholesale Price Standard Flash Column - SepaFlash™ HP Series – Santai

Wholesale Price Standard Flash Column - SepaFlash™ HP Series – Santai

Short Description:


Product Detail

REFERENCE

Application

Video

Related Video

Feedback (2)

Often customer-oriented, and it's our ultimate target to become not only probably the most reputable, trustable and honest provider, but also the partner for our customers for Sepabean, 1600G Flash Column, 1600G Flash Column, We are seeking for extensive cooperation with honest customers, achieving a new cause of glory with customers and strategic partners.
Wholesale Price Standard Flash Column - SepaFlash™ HP Series – Santai Detail:

HP series flash columns are spin-welded and allow for higher pressure of up to 400 psi. Available adapter facilitates compatibility with any flash system on the market. This series provides Luer-Lok in and Luer-Lok out flexibility for convenient column stacking. When pre-packed with high-efficiency silica gel (irregular, 25-40 μm, 60 Å; spherical, 20-45 μm, 70 Å), this series presents an outstanding resolution over conventional flash cartridges.

※ Solid, one-piece polypropylene body with thick walls for safety
※ Freely choose irregular silica or spherical silica according to your personal preference
※ Markedly improved resolution and higher sample loading capability
※ Spherical silica provides improved performance without increasing the system backpressure

For spherical silica gel, strict quality controls from raw material to finished product ensures high lot-to-lot reproducibility and tightly controlled specifications.

※Consistency, reliability, reproducibility
※No contamination, lower backpressure 
※Superior resolution
※Symmetrical peaks with no tailing
※Higher sample loading capacity

spherical

UltraPure irregular silica, 40−63 µm, 60 Å (surface area 500 m2 /g, pH 6.5–7.5, loading capacity 0.1–10%)

Item Number Column Size Sample Size(g) Flow Rate(mL/min) Cartridge Length (cm) Cartridge ID (mm) Max. Pressure(psi/bar) Quantity per Box
Small Big
SW-5101-004 4 g 4 mg–0.4 g 15–40 113.8 12.4 400/27.5 24 120
SW-5101-012 12 g 12 mg–1.2 g 30–60 134.8 21.4 400/27.5 24 108
SW-5101-025 25 g 25 mg–2.5 g 30–60 184 21.4 400/27.5 18 72
SW-5101-040 40 g 40 mg–4.0 g 40–70 184.4 26.7 400/27.5 12 48
SW-5101-080 80 g 80 mg–8.0 g 50–100 257.4 31.2 350/24.0 10 20
SW-5101-120 120 g 120 mg–12 g 60–150 261.5 38.6 300/20.7 8 16
SW-5101-220 220 g 220 mg–22 g 80–220 223.5 61.4 300/20.7 4 8
SW-5101-330 330 g 330 mg–33 g 80–220 280.2 61.4 250/17.2 3 6

※ Compatible with all flash chromatography systems on the market.

High-efficiency irregular silica, 25−40 µm, 60 Å (surface area 500 m2 /g, pH 6.5–7.5, loading capacity 0.1–15%)

Item Number Column Size Sample Size(g) Flow Rate(mL/min) Cartridge Length (cm) Cartridge ID (mm) Max. Pressure(psi/bar) Quantity per Box
Small Big
SW-5102-004 4 g 4 mg–0.6 g 15–30 113.8 12.4 400/27.5 24 120
SW-5102-012 12 g 12 mg–1.8 g 25–50 134.8 21.4 400/27.5 24 108
SW-5102-025 25 g 25 mg–3.8 g 25–50 184 21.4 400/27.5 18 72
SW-5102-040 40 g 40 mg–6.0 g 30–60 184.4 26.7 400/27.5 12 48
SW-5102-080 80 g 80 mg–12 g 40–80 257.4 31.2 350/24.0 10 20
SW-5102-120 120 g 120 mg–18 g 45–90 261.5 38.6 300/20.7 8 16
SW-5102-220 220 g 220 mg–33 g 60–120 223.5 61.4 300/20.7 4 8
SW-5102-330 330 g 330 mg–50 g 60–120 280.2 61.4 250/17.2 3 6

※ Compatible with all flash chromatography systems on the market.

UltraPure spherical silica, 40−75 µm, 70 Å (surface area 500 m2 /g, pH 6.0–8.0, loading capacity 0.1–10%)

Item Number Column Size Sample Size(g) Flow Rate(mL/min) Cartridge Length (cm) Cartridge ID (mm) Max. Pressure(psi/bar) Quantity per Box
Small Big
SW-2101-004-SP 4 g 4 mg–0.4 g 15–40 113.8 12.4 400/27.5 24 120
SW-2101-012-SP 12 g 12 mg–1.2 g 30–60 134.8 21.4 400/27.5 24 108
SW-2101-025-SP 25 g 25 mg–2.5 g 30–60 184 21.4 400/27.5 18 72
SW-2101-040-SP 40 g 40 mg–4.0 g 40–70 184.4 26.7 400/27.5 12 48
SW-2101-080-SP 80 g 80 mg–8.0 g 50–100 257.4 31.2 350/24.0 10 20
SW-2101-120-SP 120 g 120 mg–12 g 60–150 261.5 38.6 300/20.7 8 16
SW-2101-220-SP 220 g 220 mg–22 g 80–220 223.5 61.4 300/20.7 4 8
SW-2101-330-SP 330 g 330 mg–33 g 80–220 280.2 61.4 250/17.2 3 6

※Compatible with all flash chromatography systems on the market.

High-efficiency spherical silica, 20−45 µm, 70 Å (surface area 500 m2 /g, pH 6.0–8.0, loading capacity 0.1–15%)

Item Number Column Size Sample Size(g) Flow Rate(mL/min) Cartridge Length (cm) Cartridge ID (mm) Max. Pressure(psi/bar) Quantity per Box
SW-2102-004-SP 4 g 4 mg–0.6 g 15–30 113.8 12.4 400/27.5 24
SW-2102-012-SP 12 g 12 mg–1.8 g 25–50 134.8 21.4 400/27.5 24
SW-2102-025-SP 25 g 25 mg–3.8 g 25–50 184 21.4 400/27.5 18
SW-2102-040-SP 40 g 40 mg–6.0 g 30–60 184.4 26.7 400/27.5 12
SW-2102-080-SP 80 g 80 mg–12 g 40–80 257.4 31.2 350/24.0 10
SW-2102-120-SP 120 g 120 mg–18 g 45–90 261.5 38.6 300/20.7 8
SW-2102-220-SP 220 g 220 mg–33 g 60–120 223.5 61.4 300/20.7 4
SW-2102-330-SP 330 g 330 mg–50 g 60–120 280.2 61.4 250/17.2 3

※Compatible with all flash chromatography systems on the market.

Purification of compounds that are difficult to separate by flash chromatography (ΔRf ≤ 0.2 between spots on TLC) often results in additional steps such as subsequent purification by preparative scale HPLC. It is possible to reduce the amount of additional work required for purification by simply stacking several prepacked SepaFlash™ columns end to end on a flash chromatography system.

In liquid chromatography, chemical species are separated on the basis of their differences in velocity as they move through the column. Increasing column length can significantly increase resolution. By stacking columns end to end the length to diameter (L to D) ratio is increased so that no major changes to the media and solvent system are necessary. Often this increased L to D is sufficient to provide successful separation of difficult mixtures due to close compounds retention time that is not obtained on a single column. The data illustrates the linear relationship between the resolution and overall column length.

HP1
HP

The Highest Purification Performance Available
HP series flash columns are precisely manufactured with high-capacity silica gel, and deliver the highest purification performance. The high-capacity spherical silica has 40% higher surface area, doubling the loading capacity of lower surface area silica.
※ High-capacity silica with 40% more surface area.
※ Higher loading means smaller, faster and cheaper cartridges can be used for any separation.
※ Less solvent required.
※ The highest peak resolution.

High-capacity spherical silica, 25 µm, 50 Å (surface area 700 m2 /g, pH 5.0–8.0, loading capacity 0.1–30%)

Item Number Column Size Sample Size(g) Flow Rate(mL/min) Cartridge Length (cm) Cartridge ID (mm) Max. Pressure(psi/bar) Quantity per Box
Small Big
SW-2102-004-SP(H) 4 g 4 mg–1.2 g 15–30 113.8 12.4 400/27.5 24 120
SW-2102-012-SP(H) 12 g 12 mg–3.6 g 25–50 134.8 21.4 400/27.5 24 108
SW-2102-025-SP(H) 25 g 25 mg–7.5 g 25–50 184 21.4 400/27.5 18 72
SW-2102-040-SP(H) 40 g 40 mg–12 g 30–60 184.4 26.7 400/27.5 12 48
SW-2102-080-SP(H) 80 g 80 mg–24 g 40–80 257.4 31.2 350/24.0 10 20
SW-2102-120-SP(H) 120 g 120 mg–36 g 45–90 261.5 38.6 300/20.7 8 16
SW-2102-220-SP(H) 220 g 220 mg–66 g 60–120 223.5 61.4 300/20.7 4 8
SW-2102-330-SP(H) 330 g 330 mg–99 g 60–120 280.2 61.4 250/17.2 3 6

※ Compatible with all flash chromatography systems on the market.

High-capacity spherical silica, 15 µm, 50 Å (NEW Product) (surface area 700 m2 /g, pH 5.0–8.0, loading capacity 0.1–30%)

Item Number Column Size Sample Size(g) Flow Rate(mL/min) Cartridge Length (cm) Cartridge ID (mm) Max. Pressure(psi/bar) Quantity per Box
Small Big
SW-2103-004-SP(H) 4 g 4 mg–1.2 g 10–15 113.8 12.4 400/27.5 24 120
SW-2103-012-SP(H) 12 g 12 mg–3.6 g 15–20 134.8 21.4 400/27.5 24 108
SW-2103-025-SP(H) 25 g 25 mg–7.5 g 15–20 184 21.4 400/27.5 18 72
SW-2103-040-SP(H) 40 g 40 mg–12 g 20–30 184.4 26.7 400/27.5 12 48
SW-2103-080-SP(H) 80 g 80 mg–24 g 30–40 257.4 31.2 350/24.0 10 20
SW-2103-120-SP(H) 120 g 120 mg–36 g 35–45 261.5 38.6 300/20.7 8 16
SW-2103-220-SP(H) 220 g 220 mg–66 g 50–65 223.5 61.4 300/20.7 4 8
SW-2103-330-SP(H) 330 g 330 mg–99 g 50–65 280.2 61.4 250/17.2 3 6

※ Compatible with all flash chromatography systems on the market.

Double Loading Capacity of SepaFlash™ Cartridges pre-packed with high-capacity silica gel (700 m2 /g for 50 Å pore size) delivers the highest purification performance. The high-capacity 25 µm or 15 µm spherical silica has 40% higher surface area, doubling the loading capacity of lower surface area silica. Santai evaluated the performance of the SepaFlash™ columns compared to two well-known brands. Results show SepaFlash™ outperforms the competitors.

HP3
HP4


Product detail pictures:

Wholesale Price Standard Flash Column - SepaFlash™ HP Series – Santai detail pictures


Related Product Guide:

We are convinced that with joint efforts, the business between us will bring us mutual benefits. We can assure you product quality and competitive price for Wholesale Price Standard Flash Column - SepaFlash™ HP Series – Santai , The product will supply to all over the world, such as: Turkey, Toronto, Lyon, Our main objectives are to provide our customers worldwide with good quality, competitive price, satisfied delivery and excellent services. Customer satisfaction is our main goal. We welcome you to visit our showroom and office. We are looking forward to establish business relation with you.
  • Good quality and fast delivery, it's very nice. Some products have a little bit problem, but the supplier replaced timely, overall, we are satisfied.
    5 Stars By Nydia from Maldives - 2017.11.12 12:31
    Adhering to the business principle of mutual benefits, we have a happy and successful transaction, we think we will be the best business partner.
    5 Stars By Heather from Sri Lanka - 2018.06.28 19:27
    Write your message here and send it to us