– SepaPrep™ STR Series


NEW PRODUCT


SepaPrep™ STR Series


Robust Reversed-Phase Columns Designed for Stable Performance and Contamination Resistance


Series Overview


The SepaPrep™ STR Series is engineered by carefully balancing pore size, surface area, and carbon loading to deliver robust retention, reliable resolution, and enhanced resistance to contamination, with STR referring to Stable and Robust performance. This design makes SepaPrep™ STR columns particularly well suited for routine analytical workflows involving complex or challenging sample matrices.


By employing a lower surface area silica compared to conventional reversed-phase columns, the SepaPrep™ STR Series reduces the number of active adsorption sites. This contributes to improved stability, cleaner separations, and extended operational lifetime, especially in applications where column fouling is a concern.


Key Features



Improved Resistance to Contamination: Reduced surface area limits non-specific adsorption, helping maintain stable performance with complex or poorly characterized samples.

Extended Column Lifetime: Designed to maintain performance over prolonged use, reducing downtime and replacement frequency.

Reliable Reversed-Phase Retention: Balanced hydrophobic interactions deliver predictable retention and resolution for routine analytical separations.



Silica Characteristics





























PhaseUSP CodeParticle SizePore SizeSpecific Surface AreaEndcappingCarbon LoadpH Range
C18L15 µm150 Å200 m2/gDouble15 %1.5 - 9.0
C8L75 µm150 Å200 m2/gSingle8 %1.5 - 8.5


To maintain consistent performance and extend the working life of the column, it is recommended to operate the SepaPrep™ STR within its optimal pH range of 2.0 to 6.0. The maximum operating temperature is 60°C and the maximum pressure rating is 5,800 psi (40 MPa). For routine operation, pressure below 2,900 psi (20 MPa) is recommended.


Ordering Information


































































































































































































Column TypeID × LengthPhaseParticle SizePore DiameterPart Number
Analytical Columns
Analytical4.6 × 150 mmC185 µm150 ÅSH-210505-004X150
Analytical4.6 × 150 mmC85 µm150 ÅSH-090505-004X150
Analytical4.6 × 250 mmC185 µm150 ÅSH-210505-004X250
Analytical4.6 × 250 mmC85 µm150 ÅSH-090505-004X250
Preparative Columns
Preparative10 × 150 mmC185 µm150 ÅSH-210505-010X150
Preparative10 × 150 mmC85 µm150 ÅSH-090505-010X150
Preparative10 × 250 mmC185 µm150 ÅSH-210505-010X250
Preparative10 × 250 mmC85 µm150 ÅSH-090505-010X250
Preparative21.2 × 150 mmC185 µm150 ÅSH-210505-021X150
Preparative21.2 × 150 mmC85 µm150 ÅSH-090505-021X150
Preparative21.2 × 250 mmC185 µm150 ÅSH-210505-021X250
Preparative21.2 × 250 mmC85 µm150 ÅSH-090505-021X250
Preparative30 × 150 mmC185 µm150 ÅSH-210505-030X150
Preparative30 × 150 mmC85 µm150 ÅSH-090505-030X150
Preparative30 × 150 mmC185 µm150 ÅSH-210505-030X250
Preparative30 × 250 mmC85 µm150 ÅSH-090505-030X250
Guard Columns
Guard4.6 × 10 mmC185 µm150 ÅSG-210505-004X10N (or D)
Guard4.6 × 10 mmC85 µm150 ÅSG-090505-004X10N (or D)
Guard10 × 10 mmC185 µm150 ÅSG-210505-010X10D
Guard10 × 10 mmC85 µm150 ÅSG-090505-010X10D
Guard21.2 × 10 mmC185 µm150 ÅSG-210505-021X10N
Guard21.2 × 10 mmC85 µm150 ÅSG-090505-021X10N