– SepaPrep™ LPS Series


NEW PRODUCT


SepaPrep™ LPS Series


Low-pH Stable Reversed-Phase Columns for Acidic and LC-MS Applications


Series Overview


The SepaPrep™ LPS Series is specifically engineered to deliver exceptional stability and reproducible performance under strongly acidic conditions, with LP referring to Low pH and S indicating enhanced stability, while remaining fully compatible with highly aqueous mobile phases. The stationary phase is intentionally non-endcapped and built on a sterically protected bonding architecture that shields critical siloxane linkages from acid-driven degradation.


This design enables reliable operation at pH values as low as 0.8, with very low phase bleed and excellent chromatographic stability. As a result, SepaPrep™ LPS columns are particularly well suited for LC-MS workflows, impurity profiling, and the separation of highly polar analytes under acidic conditions.


Key Features



Exceptional Stability Under Strongly Acidic Conditions: Sterically protected, non-endcapped bonding architecture enables reliable operation at pH values as low as 0.8 while maintaining long-term chromatographic stability.

Fully Compatible With 100 % Aqueous Mobile Phases: Maintains retention and efficiency under fully aqueous or high-water conditions without loss of performance.

Low Phase Bleed for LC-MS Workflows: Optimized stationary-phase chemistry ensures stable baselines and excellent compatibility with mass spectrometry.



Silica Characteristics







































PhaseUSP CodeParticle SizePore SizeSpecific Surface AreaEndcappingCarbon LoadpH Range
C18L13, 5 & 10 µm150 Å200 m2/gNon-endcapped12 %0.8 - 7.5
C18 (WP)L15 µm300 Å80 m2/gNon-endcapped5 %0.8 - 7.5
C8L75 µm150 Å200 m2/gNon-endcapped7 %1.0 - 7.5


To maintain consistent performance and extend the working life of the column, it is recommended to operate the SepaPrep™ LPS within its optimal pH range of 1.0 to 4.0. The maximum operating temperature is 60°C and the maximum pressure rating is 5,800 psi (40 MPa). For routine operation, pressure below 2,900 psi (20 MPa) is recommended.


Ordering Information


























































































































































































































Column TypeID × LengthPhaseParticle SizePore DiameterPart Number
Analytical Columns
Analytical4.6 × 150 mmC183 µm150 ÅSH-220305-004X150
Analytical4.6 × 150 mmC185 µm150 ÅSH-220505-004X150
Analytical4.6 × 150 mmC18 (WP)5 µm300 ÅSH-220507-004X150
Analytical4.6 × 150 mmC85 µm150 ÅSH-110505-004X150
Analytical4.6 × 250 mmC183 µm150 ÅSH-220305-004X250
Analytical4.6 × 250 mmC185 µm150 ÅSH-220505-004X250
Analytical4.6 × 250 mmC18 (WP)5 µm300 ÅSH-220507-004X250
Analytical4.6 × 250 mmC85 µm150 ÅSH-110505-004X250
Preparative Columns
Preparative10 × 150 mmC185 µm150 ÅSH-220505-010X150
Preparative10 × 150 mmC1810 µm150 ÅSH-221005-010X150
Preparative10 × 250 mmC185 µm150 ÅSH-220505-010X250
Preparative10 × 250 mmC1810 µm150 ÅSH-221005-010X250
Preparative21.2 × 150 mmC185 µm150 ÅSH-220505-021X150
Preparative21.2 × 150 mmC1810 µm150 ÅSH-221005-021X150
Preparative21.2 × 250 mmC185 µm150 ÅSH-220505-021X250
Preparative21.2 × 250 mmC1810 µm150 ÅSH-221005-021X250
Preparative30 × 150 mmC185 µm150 ÅSH-220505-030X150
Preparative30 × 150 mmC1810 µm150 ÅSH-221005-030X150
Preparative30 × 250 mmC185 µm150 ÅSH-220505-030X250
Preparative30 × 250 mmC1810 µm150 ÅSH-221005-030X250
Preparative50 × 250 mmC1810 µm150 ÅSH-221005-050X250
Guard Columns
Guard4.6 × 10 mmC183 µm150 ÅSG-220305-004X10N (or D)
Guard4.6 × 10 mmC185 µm150 ÅSG-220505-004X10N (or D)
Guard10 × 10 mmC185 µm150 ÅSG-220505-010X10D
Guard21.2 × 10 mmC185 µm150 ÅSG-220505-021X10N