– SepaPrep™ HILIC


NEW PRODUCT


SepaPrep™ HILIC


Hydrophilic Interaction Chromatography for Highly Polar and Water-Soluble Compounds


Series Overview


The SepaPrep™ HILIC is designed for separations where reversed-phase chromatography provides insufficient retention. Operating in hydrophilic interaction chromatography (HILIC) mode, analytes are separated based on increasing hydrophilicity using mobile phases composed of acetonitrile mixed with water and volatile buffer salts, with acetonitrile content typically ranging from 40 to 97%.


The SepaPrep™ HILIC stationary phase is based on a chemically bonded amide functionality, providing strong and reproducible hydrophilic interactions while maintaining excellent stability. This chemistry delivers selectivity that complements reversed-phase methods and supports the use of highly volatile, MS-friendly mobile phases, making the series particularly well suited for LC-MS applications.


Key Features



Wide Operational Range in HILIC Mode: Provides stable retention and selectivity across a broad organic solvent composition window, offering excellent flexibility during method development and optimization.

Amide-Bonded Stationary Phase for Polar Analytes: Optimized for highly polar and water-soluble compounds with improved reproducibility versus amino and bare silica phases.

Robust, MS-Friendly Alternative to Amino and Bare Silica Phases: Offers enhanced chemical stability, reduced moisture sensitivity, and longer service life, while enabling the use of volatile mobile phases for LC-MS workflows.



Silica Characteristics



















PhaseUSP CodeParticle SizePore SizeSpecific Surface AreaEndcappingCarbon LoadpH Range
HILIC-5 & 10 µm100 Å380 m2/gNon-endcapped8 %2.0 - 8.0


To maintain consistent performance and extend the working life of the column, it is recommended to operate the SepaPrep™ HILIC within its optimal pH range of 2.0 to 8.0. The maximum operating temperature is 60°C and the maximum pressure rating is 5,800 psi (40 MPa). For routine operation, pressure below 2,900 psi (20 MPa) is recommended.


Ordering Information


























































































































































































Column TypeID × LengthPhaseParticle SizePore DiameterPart Number
Analytical Columns
Analytical4.6 × 150 mmHILIC5 µm100 ÅSH-650502-004X150
Analytical4.6 × 150 mmHILIC10 µm100 ÅSH-651002-004X150
Analytical4.6 × 250 mmHILIC5 µm100 ÅSH-650502-004X250
Analytical4.6 × 250 mmHILIC10 µm100 ÅSH-651002-004X250
Preparative Columns
Preparative10 × 150 mmHILIC5 µm100 ÅSH-650502-010X150
Preparative10 × 150 mmHILIC10 µm100 ÅSH-651002-010X150
Preparative10 × 250 mmHILIC5 µm100 ÅSH-650502-010X250
Preparative10 × 250 mmHILIC10 µm100 ÅSH-651002-010X250
Preparative21.2 × 150 mmHILIC5 µm100 ÅSH-650502-021X150
Preparative21.2 × 150 mmHILIC10 µm100 ÅSH-651002-021X150
Preparative21.2 × 250 mmHILIC5 µm100 ÅSH-650502-021X250
Preparative21.2 × 250 mmHILIC10 µm100 ÅSH-651002-021X250
Preparative30 × 150 mmHILIC5 µm100 ÅSH-650502-030X150
Preparative30 × 250 mmHILIC5 µm100 ÅSH-650502-030X250
Preparative50 × 250 mmHILIC10 µm100 ÅSH-651002-050X250
Guard Columns
Guard4.6 × 10 mmHILIC5 µm100 ÅSG-650502-004X10N (or D)
Guard4.6 × 10 mmHILIC10 µm100 ÅSG-651002-004X10N (or D)
Guard10 × 10 mmHILIC5 µm100 ÅSG-650502-010X10D
Guard10 × 10 mmHILIC10 µm100 ÅSG-651002-010X10D
Guard21.2 × 10 mmHILIC5 µm100 ÅSG-650502-021X10N
Guard21.2 × 10 mmHILIC10 µm100 ÅSG-651002-021X10N