SepaFlash™ HP Series
Series HP columnae mico iuncta sunt ac permittunt ut altioris pressionis usque ad 400 psi.Praesto adaptor faciliorem reddit compatibilitatem cum aliqua systemate mico in foro.Haec series praebet Luer-Lok in et Luer-Lok e flexibilitatem convenientis columnae positis.Cum prae-conferta alta efficacia gel silica (irregularis, 25-40 µm, 60 ; sphaerica, 20-45 µm, 70 ), haec series egregiam resolutionem praebet super cartridges mico conventionali.
Silica vel sphaerica silica irregularis libere elige secundum personalem preference
Conspicue melius resolutio et altior specimen loading facultatem
Sphaerica silica meliorem efficiendi rationem praebet sine incremento systematis backpressure
Nam globosa silica gel, qualitas stricte a materia rudis ad opus perfectum moderatur, multum-ad-multum efficit reproducibilitatem et specificationes arcte moderandas.
Constantia, commendatio, reproducibilitas
Nulla contagione minus backpressure
Superius senatus
Symmetrica cacumina nihil tendentem
Superius sample facultatem loading
Summus vis irregularis silica, 25−40 µm, 60(Superficiem area D m *2/g, pH 6.5-7.5, facultatem loading 0.1-15%)
Item numerus | Columna Location | Magnitudine exempli (g) | Fluunt Rate(mL/min) | Adapter Longitudo (cm) | Adapter ID (mm) | Maximilianus.Pressura (psi / talea) | Quantitas per Box | |
Parvus | Magna | |||||||
SW-5102-004 | 4g | 4mg-0.6g | 15-30 | 113.8 | 12.4 | 400/27.5 | 24 | 120 |
SW-5102-012 | 12g | 12mg-1.8g | 25-50 | 134.8 | 21.4 | 400/27.5 | 24 | 108 |
SW-5102-025 | 25g | 25mg-3.8g | 25-50 | 184 | 21.4 | 400/27.5 | 18 | 72 |
SW-5102-040 | 40g | 40mg-6.0g | 30-60 | 184.4 | 26.7 | 400/27.5 | 12 | 48 |
SW-5102-080 | 80g | 80mg-12g | 40-80 | 257.4 | 31.2 | 350/24.0 | 10 | 20 |
SW-5102-120 | 120g | 120mg-18g | 45–90 | 261.5 | 38.6 | 300/20.7 | 8 | 16 |
SW-5102-220 | 220g | 220mg-33g | 60-120 | 223.5 | 61.4 | 300/20.7 | 4 | 8 |
SW-5102-330 | 330g | 330mg-50g | 60-120 | 280.2 | 61.4 | 250/17.2 | 3 | 6 |
SW-5102-800 | 800g | 800mg-120g | 50-100 | 382.9 | 78.2 | 100/6.9 | 3 | - |
SW-5102-1600 | 1600g | 1.6g-240g | 50-100 | 432.4 | 103.8 | 100/6.9 | 2 | - |
SW-5102-3000 | 3kg | 3g-450g | 50-100 | 509.5 | 127.5 | 100/6.9 | 1 | - |
SW-5102-5000 | 5kg | 5g-750g | 50-100 | 770 | 127.5 | 100/6.9 | 1 | - |
SW-5102-010K | 10kg | 10g-1.5kg | 50-100 | 850 | 172.5 | 100/6.9 | 1 | - |
※ Compatible cum omnibus systematibus chromatographiae mico in foro.
Purificatio compositorum quae difficilia sunt ad separandum chromatographia mico (ΔRf ≤ 0.2 inter maculas TLC) saepe evenit in gradibus additis sicut sequens purificatio per scalam praeparativam HPLC.Fieri potest reducere amounts additici operis ad purificationem requisiti, simpliciter positis pluribus columnis SepaFlash praepeditis, ut finiatur ratio chromatographiae mico.
In chromatographia liquida, species chemicae ob differentias velocitatis earum per columnam moventes separantur.Augens columna longitudo signanter solutionem augere potest.Acclinatis columnis finem longitudinis ad diametri (L ad D) ratio augetur, ut nullae majores mutationes in instrumentis et systematis solvendo sint necessariae.Saepe hoc L ad D auctum satis est providere felicissimae mixturae difficilium separationem propter retentione compositarum prope tempus quod in una columna non obtinetur.Notitia relationem linearem illustrat inter solutionem et altiorem columnam longitudinis.
Ultra Pure sphaericam silicam, 40−75 µm, 70(Superficiem area D m *2/g, pH 6.0-8.0, facultatem loading 0.1-10%)
Item numerus | Columna Location | Magnitudine exempli (g) | Fluunt Rate(mL/min) | Adapter Longitudo (cm) | Adapter ID (mm) | Maximilianus.Pressura (psi / talea) | Quantitas per Box | |
Parvus | Magna | |||||||
SW-2101-004-SP | 4g | 4mg-0.4g | 15-40 | 113.8 | 12.4 | 400/27.5 | 24 | 120 |
SW-2101-012-SP | 12g | 12mg–1.2g | 30-60 | 134.8 | 21.4 | 400/27.5 | 24 | 108 |
SW-2101-025-SP | 25g | 25mg–2.5g | 30-60 | 184 | 21.4 | 400/27.5 | 18 | 72 |
SW-2101-040-SP | 40g | 40mg–4.0g | 40-70 | 184.4 | 26.7 | 400/27.5 | 12 | 48 |
SW-2101-080-SP | 80g | 80mg–8.0g | 50-100 | 257.4 | 31.2 | 350/24.0 | 10 | 20 |
SW-2101-120-SP | 120g | 120mg-12g | 60-150 | 261.5 | 38.6 | 300/20.7 | 8 | 16 |
SW-2101-220-SP | 220g | 220mg-22g | 80-220 | 223.5 | 61.4 | 300/20.7 | 4 | 8 |
SW-2101-330-SP | 330g | 330mg–33g | 80-220 | 280.2 | 61.4 | 250/17.2 | 3 | 6 |
SW-2101-800-SP | 800g | 800mg-80g | 50-100 | 382.9 | 78.2 | 100/6.9 | 3 | - |
SW-2101-1600-SP | 1600g | 1.6g-160g | 50-100 | 432.4 | 103.8 | 100/6.9 | 2 | - |
SW-2101-3000-SP | 3kg | 3g-300g | 50-100 | 509.5 | 127.5 | 100/6.9 | 1 | - |
SW-2101-5000-SP | 5kg | 5g-500g | 50-100 | 770 | 127.5 | 100/6.9 | 1 | - |
SW-2101-010K-SP | 10kg | 10g-1kg | 50-100 | 850 | 172.5 | 100/6.9 | 1 | - |
※ Compatible cum omnibus systematibus chromatographiae mico in foro.
Summus vis sphaerica silica, 20−45 µm, 70(Superficiem area D m *2/g, pH 6.0-8.0, facultatem loading 0.1-15%)
Item numerus | Columna Location | Magnitudine exempli (g) | Fluunt Rate(mL/min) | Adapter Longitudo (cm) | Adapter ID (mm) | Maximilianus.Pressura (psi / talea) | Quantitas per Box | |
Parvus | Magna | |||||||
SW-2102-004-SP | 4g | 4mg-0.6g | 15-30 | 113.8 | 12.4 | 400/27.5 | 24 | 120 |
SW-2102-012-SP | 12g | 12mg–1.8g | 25-50 | 134.8 | 21.4 | 400/27.5 | 24 | 108 |
SW-2102-025-SP | 25g | 25mg–3.8g | 25-50 | 184 | 21.4 | 400/27.5 | 18 | 72 |
SW-2102-040-SP | 40g | 40mg–6.0g | 30-60 | 184.4 | 26.7 | 400/27.5 | 12 | 48 |
SW-2102-080-SP | 80g | 80mg-12g | 40-80 | 257.4 | 31.2 | 350/24.0 | 10 | 20 |
SW-2102-120-SP | 120g | 120mg-18g | 45–90 | 261.5 | 38.6 | 300/20.7 | 8 | 16 |
SW-2102-220-SP | 220g | 220mg–33g | 60-120 | 223.5 | 61.4 | 300/20.7 | 4 | 8 |
SW-2102-330-SP | 330g | 330mg-50g | 60-120 | 280.2 | 61.4 | 250/17.2 | 3 | 6 |
SW-2102-800-SP | 800g | 800mg-120g | 50-100 | 382.9 | 78.2 | 100/6.9 | 3 | - |
SW-2102-1600-SP | 1600g | 1.6g-240g | 50-100 | 432.4 | 103.8 | 100/6.9 | 2 | - |
SW-2102-3000-SP | 3kg | 3g-450g | 50-100 | 509.5 | 127.5 | 100/6.9 | 1 | - |
SW-2102-5000-SP | 5kg | 5g-750g | 50-100 | 770 | 127.5 | 100/6.9 | 1 | - |
SW-2102-010K-SP | 10kg | 10g-1.5kg | 50-100 | 850 | 172.5 | 100/6.9 | 1 | - |
※ Compatible cum omnibus systematibus chromatographiae mico in foro.
Summus capacitas sphaericae silicae, 50 µm, 54(area superficiei 700 m2/g, pH 6.0‒8.0, capacitatis 0.1‒30% onerantium)
Item numerus | Columna Location | Magnitudine exempli (g) | Fluunt Rate(mL/min) | Adapter Longitudo (cm) | Adapter ID (mm) | Maximilianus.Pressura (psi / talea) | Quantitas per Box | |
Parvus | Magna | |||||||
SW-2101-004-SP(H) | 4g | 4mg–1.2g | 15-30 | 113.8 | 12.4 | 400/27.5 | 24 | 120 |
SW-2101-012-SP(H) | 12g | 12mg–3.6g | 25-50 | 134.8 | 21.4 | 400/27.5 | 24 | 108 |
SW-2101-025-SP(H) | 25g | 25mg–7.5g | 25-50 | 184 | 21.4 | 400/27.5 | 18 | 72 |
SW-2101-040-SP(H) | 40g | 40mg-12g | 30-60 | 184.4 | 26.7 | 400/27.5 | 12 | 48 |
SW-2101-080-SP(H) | 80g | 80mg-24g | 40-80 | 257.4 | 31.2 | 350/24.0 | 10 | 20 |
SW-2101-120-SP(H) | 120g | 120mg–36g | 45-90 | 261.5 | 38.6 | 300/20.7 | 8 | 16 |
SW-2101-220-SP(H) | 220g | 220mg-66g | 60-120 | 223.5 | 61.4 | 300/20.7 | 4 | 8 |
SW-2101-330-SP(H) | 330g | 330mg–99g | 60-120 | 280.2 | 61.4 | 250/17.2 | 3 | 6 |
SW-2101-800-SP(H) | 800g | 800mg-240g | 50-100 | 382.9 | 78.2 | 100/6.9 | 3 | - |
SW-2101-1600-SP(H) | 1600g | 1.6g-480g | 50-100 | 432.4 | 103.8 | 100/6.9 | 2 | - |
SW-2101-3000-SP(H) | 3kg | 3g-900g | 50-100 | 509.5 | 127.5 | 100/6.9 | 1 | - |
SW-2101-5000-SP(H) | 5kg | 5g-1.5kg | 50-100 | 770 | 127.5 | 100/6.9 | 1 | - |
SW-2101-010K-SP(H) | 10kg | 10g-3kg | 50-100 | 850 | 172.5 | 100/6.9 | 1 | - |
※ Compatible cum omnibus systematibus chromatographiae mico in foro.
Summus capacitas sphaerica silica, 25 µm, 50(Superficiem area DCC m *2/g, pH 5.0-8.0, facultatem loading 0.1-30%)
Item numerus | Columna Location | Magnitudine exempli (g) | Fluunt Rate(mL/min) | Adapter Longitudo (cm) | Adapter ID (mm) | Maximilianus.Pressura (psi / talea) | Quantitas per Box | |
Parvus | Magna | |||||||
SW-2102-004-SP(H) | 4g | 4mg–1.2g | 15-30 | 113.8 | 12.4 | 400/27.5 | 24 | 120 |
SW-2102-012-SP(H) | 12g | 12mg–3.6g | 25-50 | 134.8 | 21.4 | 400/27.5 | 24 | 108 |
SW-2102-025-SP(H) | 25g | 25mg–7.5g | 25-50 | 184 | 21.4 | 400/27.5 | 18 | 72 |
SW-2102-040-SP(H) | 40g | 40mg-12g | 30-60 | 184.4 | 26.7 | 400/27.5 | 12 | 48 |
SW-2102-080-SP(H) | 80g | 80mg-24g | 40-80 | 257.4 | 31.2 | 350/24.0 | 10 | 20 |
SW-2102-120-SP(H) | 120g | 120mg–36g | 45-90 | 261.5 | 38.6 | 300/20.7 | 8 | 16 |
SW-2102-220-SP(H) | 220g | 220mg-66g | 60-120 | 223.5 | 61.4 | 300/20.7 | 4 | 8 |
SW-2102-330-SP(H) | 330g | 330mg–99g | 60-120 | 280.2 | 61.4 | 250/17.2 | 3 | 6 |
SW-2102-800-SP(H) | 800g | 800mg-240g | 50-100 | 382.9 | 78.2 | 100/6.9 | 3 | - |
SW-2102-1600-SP(H) | 1600g | 1.6g-480g | 50-100 | 432.4 | 103.8 | 100/6.9 | 2 | - |
SW-2102-3000-SP(H) | 3kg | 3g-900g | 50-100 | 509.5 | 127.5 | 100/6.9 | 1 | - |
SW-2102-5000-SP(H) | 5kg | 5g-1.5kg | 50-100 | 770 | 127.5 | 100/6.9 | 1 | - |
SW-2102-010K-SP(H) | 10kg | 10g-3kg | 50-100 | 850 | 172.5 | 100/6.9 | 1 | - |
※ Compatible cum omnibus systematibus chromatographiae mico in foro.
Summus capacitas sphaerica silica, 15 µm, 50(Superficiem area DCC m *2/g, pH 5.0-8.0, facultatem loading 0.1-30%)
Item numerus | Columna Location | Magnitudine exempli (g) | Fluunt Rate(mL/min) | Adapter Longitudo (cm) | Adapter ID (mm) | Maximilianus.Pressura (psi / talea) | Quantitas per Box | |
Parvus | Magna | |||||||
SW-2103-004-SP(H) | 4 g* | 4 mg-1.2 g | 10-15 | 113.8 | 12.4 | 400/27.5 | 24 | 120 |
SW-2103-012-SP(H) | 12 g* | 12 mg-3.6 g | 15-20 | 134.8 | 21.4 | 400/27.5 | 24 | 108 |
SW-2103-025-SP(H) | 25 g | 25 mg-7.5 g | 15-20 | 184 | 21.4 | 400/27.5 | 18 | 72 |
SW-2103-040-SP(H) | 40 g | 40 mg-12 g | 20-30 | 184.4 | 26.7 | 400/27.5 | 12 | 48 |
SW-2103-080-SP(H) | 80 g | 80 mg-24 g | 30-40 | 257.4 | 31.2 | 350/24.0 | 10 | 20 |
SW-2103-120-SP(H) | 120 g | 120 mg-36 g | 35-45 | 261.5 | 38.6 | 300/20.7 | 8 | 16 |
SW-2103-220-SP(H) | 220 g | 220 mg-66 g | 50-65 | 223.5 | 61.4 | 300/20.7 | 4 | 8 |
SW-2103-30-SP(H) | 330 g | 330 mg-99 g | 50-65 | 280.2 | 61.4 | 250/17.2 | 3 | 6 |
※ Compatible cum omnibus systematibus chromatographiae mico in foro.
Duplex Loading Capacity of SepaFlash™ Cartridges pre-packed with high-capacity silica gel (700 m.2/g pro 50Å magnitudine) summam purificationem tradit.Summus capacitas 25 µm vel 15 µm sphaericam silicam 40% superficiem superiorem habet, duplicato oneratione capacitatis superficiei silicae inferioris.Santai perpensum faciendum in SepaFlash™ columnarum duarum notarum notarum comparatarum.Proventus monstrant SepaFlash™ competitores outperforms.
- AN006-De Purificatione Peptidis Parvi Moleculares SepaFlash™ HP Bio Series Flash Cartridge
- AN009-Purificatio Porphyrii per apparatus SepaBean™
- AN012-Applicatio SepaFlash Cartridges in Purificatione Diazoti Composita
- AN021_De applicatione Columnae Stacking in Purificatione Optoelectronic Materiae Organicae
- AN022_Higher Sample Loading facultas, Melior euismod - Applicatio SepaFlash™ Ruby High Consilium Cartridges
- AN023_SepaFlash™ Ruby Series High Resolution Normal Phase Silicone Column Reuse and Storage Guide
- AN-SS-007-Reusable Santai SepaFlash™ Ruby Series Columnae Separatio usque ad C temporibus
- SepaFlash column Catalog EN