paj_banner

SepaFlash™ Standard Series

SepaFlash™ Standard Series

Lus piav qhia luv luv:

Standard Series flash kab yog tshuab ntim nrog UltraPure silica gel siv cov txheej txheem qhuav ntim khoom.

※ UltraPure silica nta nruj particle loj tis, theem qis ntawm kev nplua thiab cov ntsiab lus hlau tsis tshua muaj, nruab nrab pH, tswj cov ntsiab lus dej thiab thaj chaw siab, muab cov kws tshawb fawb xav tau cov txiaj ntsig kev sim rov ua dua tshiab.

※ Tshwj xeeb, cov txheej txheem qhuav ntim cov txheej txheem lav qhov kev daws teeb meem siab thiab rov tsim dua tshiab rau kev ua kom huv txhua hnub.

※ Txhim kho siab ntsuas txog 300 psi.


Product Detail

Daim ntawv thov

Video

catalog

Khoom Taw Qhia

Standard Series flash kab yog tshuab ntim nrog UltraPure silica gel siv cov txheej txheem qhuav ntim khoom.

※ UltraPure silica nta nruj particle loj faib, qib qis ntawm kev nplua thiab cov ntsiab lus hlau tsis tshua muaj, nruab nrab pH, tswj cov dej thiab thaj chaw siab, muab cov kws tshawb fawb xav tau cov txiaj ntsig kev sim rov ua dua.
※ Tshwj xeeb, cov txheej txheem qhuav ntim cov txheej txheem lav kev daws teeb meem siab thiab rov tsim dua tshiab rau kev ua kom huv txhua hnub.
※ Txhim kho qhov siab txog li 300 psi

Khoom Parameters

UltraPure irregular silica, 40-63 µm, 60 Å(qhov chaw thaj tsam 500 m2/g, pH 6.5-7.5, loading peev 0.1-10%)
Yam khoom naj npawb Kem Loj Qauv Loj (g) Tus nqi ntws (mL / min) Cartridge Ntev (cm) Cartridge ID (hli) Max.Siab (psi / bar) Quantity/Box
Me me Loj
S-5101-0004 4 g ib 4 mg – 0.4 g 15–40 : kuv 105.8 ib 12.4 300/20.7 36 120
S-5101-0012 12g ua 12 mg – 1.2 g 30–60 : kuv 124.5 ib 21.2 300/20.7 24 108
S-5101-0025 25g ua 25 mg-2.5 g 30–60 : kuv 172.7 ib 21.3 300/20.7 20 80
S-5101-0040 40g ua 40 mg-4.0 g 40–70 : kuv 176 26.7 ib 300/20.7 15 60
S-5101-0080 80g ua 80 mg-8.0 g 50–100 248.5 ib 30.9 ib 200/13.8 10 20
S-5101-0120 120 g 120 mg-12 g 60–150 : kuv 261.5 ib 37.2 ib 200/13.8 8 16
S-5101-0220 22 0g 220 mg-22 g 80–220 : kuv 215.9 ib 59.4 ib 150/10.3 4 8
S-5101-0330 330g ua 330 mg-33 g 80–220 : kuv 280.3 ib 59.8 ua 150/10.3 3 6
S-5101-0800 8 00g 800 mg-80 g 100-300 382.9 ib 78.2 ib 100/6.9 3 /
S-5101-1600 1600 g 1.6-160 g yog ' 200-500 432.4 ib 103.8 ib 100/6.9 2 /
S-5101-3000 3000 g 3.0-300 g yog ' 200-500 509.5 ib 127.5 ib 100/6.9 1 /

※ Tau tshaj txhua lub tshuab flash chromatography ntawm lub khw.

High-zoo irregular alumina, 50-75 µm, 55 Å(pH: acidic 3.8-4.8, nruab nrab 6.5-7.5, theem pib 9.0-10.0; thaj tsam 155 m2 / g, loading peev 0.1-4%)
Rau acidic alumina, hloov "N" nrog "A" hauv cov khoom naj npawb, thiab rau cov alumina yooj yim nrog "B".
Yam khoom naj npawb Kem Loj Qauv Loj(g) Tus nqi ntws(ml / min) Cartridge Ntev(cm) Cartridge ID(mm) Max.Siab(psi/bar) Quantity/Box
Me me Loj
S-8601-0004-N 8g ib 8 mg-0,32 g 10–30 105.8 ib 12.4 300/20.7 36 120
S-8601-0012-N 24 g ib 24 mg – 1.0 g 15–45 : kuv 124.5 ib 21.2 300/20.7 24 108
S-8601-0025-N 50 g ib 50 mg-2.0 g 15–45 : kuv 172.7 ib 21.3 300/20.7 20 80
S-8601-0040-N 80g ua 80 mg – 3.2 g 20–50 176 26.7 ib 300/20.7 15 60
S-8601-0080-N 160 g 160 mg-6.4 g 30–70 : kuv 248.5 ib 30.9 ib 200/13.8 10 20
S-8601-0120-N 24 0g 240 mg-9.6 g 40–80 : kuv 261.5 ib 37.2 ib 200/13.8 8 16
S-8601-0220-N 440g ua 440 mg – 17.6 g 50–120 : kuv 215.9 ib 59.4 ib 150/10.3 4 8
S-8601-0330-N 660g ua 660 mg – 26.4 g 50–120 : kuv 280.3 ib 59.8 ua 150/10.3 3 6
S-8601-0800-N 1600 g 1,6g-64g 100–200 382.9 ib 78.2 ib 100/6.9 3 /
S-8601-1600-N 3 200g 3.2g-128g 150-300 Nws 432.4 ib 103.8 ib 100/6.9 2 /
S-8601-3000-N 6000 g 6.0-240 g yog ' 150-300 Nws 509.5 ib 127.5 ib 100/6.9 1 /

※ Tau tshaj txhua lub tshuab flash chromatography ntawm lub khw.

Cov ntawv thov thiab cov txiaj ntsig nrog SepaFlashflash kab

SepaFlash ™ flash kem muab kev ua tau zoo kawg li ntawm cov khoom sib tw vim yog cov silica gel zoo dua thiab cov txheej txheem ntim khoom tshiab.

S
S3

Cov yam ntxwv rau UltraPure irregular silicagel

Cov khoom siv tau zoo no muaj cov duab tsis sib xws nrog cov npoo du, qhov nqaim me me ntawm kev faib tawm thiab qib qis ntawm kev nplua los ntawm Santai, uas yuav ua kom koj lub zog sib cais thiab txuag koj lub sijhawm thiab nyiaj txiag.Cov silica gel tsis zoo muaj ob hom kev qhia tshwj xeeb, 40-63 µm thiab 25-40 µm.Tshwj xeeb tshaj yog, Santai txuas ntxiv txhim kho cov txheej txheem qhuav qhuav kom tsis tu ncua 25-40 µm silica, thiab pre-packed 25-40 µm silica cartridges yuav qhia txog lub peev xwm txawv tshaj plaw hauv kev sib cais.

SEM daim duab ntawm 40-63 μm silica gel

SEM daim duab ntawm 40-63 μm silica gel

Khoom zoo

Santai 'silica gel kuj tseem muaj cov txiaj ntsig zoo dua li cov neeg sib tw cov khoom lag luam:

Neutral pH:Lub pH ntawm Santai tsis tu ncua silica gel yog khaws cia ntawm 6.5-7.5.Qhov nruab nrab pH yog xav tau los cais cov pH rhiab heev.

Cov ntsiab lus dej ruaj khov:Cov ntsiab lus dej ntawm silica gel tuaj yeem cuam tshuam rau kev xaiv ntawm silica.Santai's silica gel tsis tu ncua muaj cov dej tswj cov ntsiab lus ntawm 4% mus rau 6%.

High deg cheeb tsam:Qhov chaw siab dua (500 m2/g rau 60 Å pore loj) muab lub zog sib cais ntau dua.

Tight particle loj tis thiab siab batch-rau-batch reproducibility: Ib tug nqaim particle loj tis yuav muab ib tug ntau homogenous packing mus sau ntau concentrated fractions thiab txo hnyav noj, uas yuav txo tau tag nrho cov nqi.Lub siab batch-rau-batch reproducibility ntawm particle loj faib fundamentally guarantees kev sib cais zoo heev.Cov ntsiab lus ntxiv thov saib daim duab SEM thiab qhov loj me me ntawm ob pawg.

Particle loj faib ntawm ob pawg rau 40-63 μm thiab 25-40 μm silica gel

Particle loj faib

TSHIAB KOM ZOO - 5 kg

SepaFlash™ kem yog tam sim no muaj nyob rau hauv 5 kg loj.
uas tuaj yeem ntxuav txog li 500 grams ntawm cov qauv hauv ib qho kev khiav.
Nws yog spin-welded thiab tuaj yeem sawv siab txog 100 psi (6.9 bar).

※ Kev ntseeg tau, ua tau zoo ib yam los ntawm cov txheej txheem ntim khoom.
※ Reinforced cartridge lub cev nrog kev ua haujlwm siab tshaj plaws txog li 100 psi.
※ Luer-Lok kawg fittings tau tshaj txhua lub tshuab flash loj hauv khw.
※ Muaj peev xwm ua tau raws li cov txheej txheem scale-up yuav tsum tau los ntawm me me mus rau pilot-scale.
※ Pre-packed flash kem pab kom ceev purification khiav kom txuag tau sij hawm thiab hnyav.
※ Cov khoom siv yas pov tseg lub cev ua kom yooj yim thiab nyab xeeb tuav pov tseg.

5kg ua

Ultra-ntshiab irregular silica, 40-63 µm, 60 Å (Tshwj xeeb khoom)(qhov chaw thaj tsam 500 m2/g, pH 6.5-7.5, loading peev 0.1-10%)

Yam khoom naj npawb Kem Loj Qauv Loj Units/Box Tus nqi ntws (mL / min) Cartridge Ntev (mm) Cartridge ID (hli) Max.Siab (psi / bar)
S-5101-5000 5kg ua 5-500 g yog ' 1 200-500 770 ib 127.5 ib 100/6.9

※ Tau tshaj txhua lub tshuab flash chromatography ntawm lub khw.

Kev sib cais zoo nrog SepaFlash™ 5 kg

Qauv:Acetophenone thiab P-Methoxyacetophenone
Mobile Phase:80% hexane thiab 20% ethyl acetate
Flow Rate:250 ml / min
Qauv Loj:60 ml ib
Wave Length:254nm ua

Kev sib cais

Chromatographic Parameters:

Kem Loj tR N Rs T
SepaFlash™ 5kg 50 feeb 617 ib 6.91 ib 1.00 Nws

TSHIAB KOM ZOO - 10 kg

※ Purify txog li 1 kg ntawm cov qauv hauv ib qho kev khiav.
※ Tshwj xeeb ntim nrog cov txheej txheem tsim khoom.
※ Kev ntseeg tau, ua tau zoo ib yam los ntawm cov txheej txheem ntim khoom
※ Reinforced cartridge lub cev nrog lub siab tshaj plaws ua haujlwm siab txog 100 psi (6.9bar)
※ Ntau yam adapters rau txawv OD tubings ua rau nws siv tau rau txhua lub tshuab flash loj hauv khw
※ Muaj peev xwm ua tau raws li cov txheej txheem scale-up yuav tsum tau los ntawm me me mus rau pilot-scale
※ Pre-packed flash kem pab kom ceev purification khiav kom txuag sij hawm thiab cov kuab tshuaj
※ Cov khoom siv yas pov tseg lub cev ua kom yooj yim thiab nyab xeeb tuav pov tseg

5kg ua

Ultra-ntshiab irregular silica, 40-63 µm, 60 Å (Tshwj xeeb khoom)(qhov chaw thaj tsam 500 m2/g, pH 6.5-7.5, loading peev 0.1-10%)

Yam khoom naj npawb Kem Loj Qauv Loj Units/Box Tus nqi ntws (mL / min) Cartridge Ntev (mm) Cartridge ID (hli) Max.Siab (psi / bar)
S-5101-010K 10 kg Yog '- 10 g 1 300-1000 850 172.5 ib 100/6.9

※ Tau tshaj txhua lub tshuab flash chromatography ntawm lub khw.

Kev sib cais zoo nrog SepaFlash ™ 10 kg

Qauv:Acetophenone thiab P-Methoxyacetophenone
Mobile Phase:80% hexane thiab 20% ethyl acetate
Flow Rate:400 ml / min
Qauv Loj:100 mL
Wave Length:254nm ua

SepaFlash

Chromatographic Parameters:

Kem Loj tR N Rs T
SepaFlash™ 10kg 65 feeb 446 ib 5.97 ib 1.22

  • Yav dhau los:
  • Tom ntej:

    • AN-SS-008 Kev Siv ntawm Santai SepaFlash ™ kem rau Kev Ncua Nroj Tsuag Cov Khoom Siv Ua Ntej ntawm Multi-gram nplai
      AN-SS-008 Kev Siv ntawm Santai SepaFlash ™ kem rau Kev Ncua Nroj Tsuag Cov Khoom Siv Ua Ntej ntawm Multi-gram nplai
    • AN005_SepaFlash ™ Loj Purification Khoom rau Ntau pua Grams ntawm Cov Qauv
      AN005_SepaFlash ™ Loj Purification Khoom rau Ntau pua Grams ntawm Cov Qauv
    • AN007_Kev thov ntawm SepaBean ™ Tshuab hauv thaj tsam ntawm Organic Optoelectronic Materials
      AN007_Kev thov ntawm SepaBean ™ Tshuab hauv thaj tsam ntawm Organic Optoelectronic Materials
    • AN011_Tau Kev Pom Zoo rau SepaBean ™ Tshuab nrog Kws Ua Haujlwm: Evaporative Light Scattering Detector
      AN011_Tau Kev Pom Zoo rau SepaBean ™ Tshuab nrog Kws Ua Haujlwm: Evaporative Light Scattering Detector
    • AN021_Kev siv cov kab hauv kev ua kom huv ntawm Organic Optoelectronic Materials
      AN021_Kev siv cov kab hauv kev ua kom huv ntawm Organic Optoelectronic Materials
    • AN024_Kev thov ntawm Orthogonal Chromatography rau kev ntxuav ntawm Synthetic Pharmaceutical Intermediates
      AN024_Kev thov ntawm Orthogonal Chromatography rau kev ntxuav ntawm Synthetic Pharmaceutical Intermediates
    Sau koj cov lus ntawm no thiab xa tuaj rau peb